Genuine Spare Parts for Oilon RP-130H Oil Burner Greens Auxiliary Boiler | Nozzle 34031077/1068, Ignition Electrode A548E, Photo Cell 36215042, Metal Flexible Oil Hose
These are genuine replacement spare parts exclusively for Oilon RP-130H oil-fired burner matched with Greens marine auxiliary boiler. The package covers core wearing parts including dual atomizing nozzles, ignition electrode, flame photocell and flexible metal oil hose. All parts follow original factory standards, direct plug-and-play replacement without modification, solving common faults such as ignition failure, poor atomization, flame detection alarm and pipeline oil leakage.
The oilon rp-130h burner parts assembly is specifically designed for technical professionals maintaining or overhauling Oilon RP-130H oil-fired burners paired with Greens marine auxiliary boilers. It targets marine engineers and maintenance teams requiring genuine components to restore or enhance system integrity. This kit’s parts address critical functional needs like ignition reliability, flame detection, precise fuel atomization, and leak prevention. Incorporating these authentic spares maintains the burner’s operational stability, safety interlocks, and performance consistency within complex marine boiler systems. Optimal integration reduces downtime and supports compliance requirements for maritime thermal equipment operation.
Key Technical Characteristics and Specifications
This comprehensive kit comprises dual atomizing nozzles for staged combustion control, the oilon ignition electrode a548e with high-temperature ceramic insulation ensuring robust spark generation, and a photo cell to provide flame-out detection linked with automatic cutoff. Alongside these, a durable metal flexible oil hose resists vibrations and corrosion, with sizes DN13 and DN20 standardized for varied fuel lines. Each component aligns fully with original equipment manufacturer tolerances, ensuring plug-and-play installation without modification. The nozzle components support both light and heavy fuel oils, reflecting the oilon rp-130h burner parts precision in matching operational demands and enhancing the overall combustion system’s efficiency and emission control.
Industry Applications and Operational Value
Primarily implemented in maritime auxiliary boiler operations, this parts kit supports the continuous functionality of onboard heating, hot water supply, and antifreeze systems. The oilon rp-130h burner parts ensure minimal disruption during overhaul scheduling and facilitate prompt resolution of ignition or flame signal failures. Their adherence to stringent marine standards enables compliance with safety protocols while maintaining fuel economy and reducing black smoke emissions.Marine boiler burner sparessupplierexpertise guarantees product authenticity and sourcing reliability, thereby reducing lifecycle costs and optimizing the operational lifespan of Greens’ marine boiler assets across commercial shipping fleets and industrial vessel applications.
Product Advantages
Modular Design and System Integration Benefits
The design of the oilon rp-130h burner parts emphasizes modularity and compatibility with existing burner assemblies, facilitating easy installation and replacement without system adaptation. The inclusion of the oilon ignition electrode a548e exemplifies precision engineering with high-voltage ceramic insulation tailored to withstand marine operational stresses. The metal flexible oil hose features a robust double-layer corrugated metal structure, enhancing durability against pipeline vibration and corrosion. As a specialized marine boiler burner spares supplier, the product structure promotes consistent system integrity and aligns with OEM quality standards, streamlining maintenance workflows and simplifying inventory management for marine service providers.
Enhanced Efficiency and Operational Reliability
Performance-wise, the kit delivers stable ignition, precise flame monitoring, and secure oil delivery which are critical for uninterrupted boiler function. Integration of the oilon ignition electrode a548e ensures reliable spark initiation under demanding conditions, while photo cell flame detection minimizes flame-out events and prevents unsafe conditions. The dual nozzles aid in optimized fuel atomization across load variations, reducing emissions and improving combustion efficiency. These attributes collectively enhance user value by reducing unscheduled downtime, improving burner lifespan, and ensuring operational safety in marine environments where compliance and performance are essential.
Product Specifications
Applicable Equipment: OIL BURNING RP-130H OILON AUX BOILER GREENS
NOZZLE NO.1 Part Number: 34031077 Specification: Primary low-load atomizing nozzle with original factory standard aperture, compatible with light fuel oil and heavy fuel oil atomization pressure
IGNITION ELECTRODE Part Number: A548E Specification: High-temperature resistant ceramic insulated high-voltage discharge electrode, matching the ignition voltage of the host burner
PHOTO CELL (Flame Detector) Part Number: 36215042 Specification: Photoelectric induction component for real-time flame light capture, equipped with flame-out interlock protection function
METAL FLEXIBLE HOSE Specification: Two sizes available (DN13 / DN20). DN13 for standard pipelines; DN20 for high-flow heavy oil pipelines. Shockproof, oil-resistant and anti-corrosion
NOZZLE NO.2 Part Number: 1068 Specification: Secondary auxiliary high-load atomizing nozzle, matched with No.1 nozzle to realize two-stage fire power regulation
Working Principle 1. NOZZLE NO.1 (34031077) Fuel flows through precision micropores inside the nozzle. Under pressure, the fuel is split into fine and uniform oil mist. This nozzle supplies fuel alone during startup to form basic low-load flame. As the core atomizing part for initial ignition, it ensures stable oil mist concentration for successful ignition. 2. IGNITION ELECTRODE (A548E) After the burner starts, the high-voltage transformer transmits high-voltage current to the electrode, generating continuous electric sparks between electrode gaps. The sparks contact the oil mist ejected from No.1 nozzle and ignite the oil-gas mixture instantly. The ceramic outer shell insulates high voltage to prevent electric leakage and short circuit. 3. PHOTO CELL (36215042) The light-sensitive surface continuously captures flame light inside the furnace and converts optical signals into electrical signals transmitted to the controller. Stable flame detected: The controller keeps the fuel valve open for continuous fuel supply and normal operation. Flame lost or extinguished: It immediately sends shutdown signals to cut off fuel supply, avoiding accumulation of unignited fuel and explosion risks through safety interlock protection. 4. METAL FLEXIBLE HOSE DN13/DN20 It serves as the fuel delivery pipeline connecting the oil pump and burner head. The corrugated telescopic structure offsets vibration generated during operation of ships and boilers, preventing fracture and oil leakage of rigid pipelines. The double-layer metal structure resists oil pressure and fuel corrosion, delivering stable fuel to nozzles without interruption. 5. NOZZLE NO.2 (1068) When the boiler needs higher temperature and thermal load, the oil circuit solenoid valve opens, and fuel flows into No.2 nozzle for secondary atomization and oil injection. It works together with No.1 nozzle for dual-oil circuit combustion, increasing total fuel supply and heating output to achieve two-stage power adjustment.
Application Scenarios Marine Supporting Industry Replacement and maintenance for Greens auxiliary boilers on bulk carriers, container ships, engineering vessels and offshore platforms; supporting cabin heating, domestic hot water supply and pipeline anti-freezing systems for ships. Industrial Thermal Equipment Spare part replacement for oil-fired steam boilers, hot water boilers and thermal oil heaters in factories. Maintenance Service Providers Consumable spare parts stocked by ship repair yards and thermal energy equipment companies. Old Equipment Renovation One-stop replacement of aging components for Oilon RP-130H burners.
Scheduled Overhaul in Marine Boiler Maintenance In commercial shipping operations, the oilon rp-130h burner parts serve as essential replacement components during routine burner maintenance cycles. Marine engineers rely on this kit to replace worn nozzles, ignition electrodes, and flame detection units to avert common issues such as ignition failure or flame-out alarms. The inclusion of the oilon ignition electrode a548e and rugged flexible oil hose assures system conformity to marine safety standards. This reliability supports uninterrupted steam generation for vessel heating demands. The kit integrates seamlessly into existing service schedules, minimizing operational interruptions and supporting effective inventory control for marine boiler burner spares supplier programs.
Emergency Repair for Combustion System Faults During unforeseen ignition or atomization faults on Greens marine auxiliary boilers, rapid deployment of the oilon rp-130h burner parts is critical. The oilon ignition electrode a548e guarantees spark reliability necessary for quick start-ups in harsh environments. The photo cell component immediately reestablishes accurate flame detection, preventing extended downtime or fuel wastage. Additionally, metal flexible oil hoses included address leak-prone pipeline sections, enhancing safety and system integrity. This kit fulfills urgent operational requirements by restoring combustion efficiency and maintaining compliance with marine environmental directives, making it an indispensable resource for marine engineers and maintenance teams.
Component Maintenance Instructions 1. NOZZLE NO.1 (34031077) & NOZZLE NO.2 (1068) Disassemble and clean carbon deposits and oil residues with diesel every 3–6 months. Replace immediately if oil mist splints, black smoke emission or difficult ignition occurs. Do not polish or enlarge the aperture, as changed bore size will damage atomization performance. 2. IGNITION ELECTRODE (A548E) Inspect ceramic insulation monthly; replace once cracks or heavy carbon deposits appear. Clean oil dirt and carbon deposits on electrode tip to maintain standard discharge gap. Handle gently during disassembly and assembly to avoid ceramic cracking and electric leakage. 3. PHOTO CELL (36215042) Wipe the front light-sensitive lens regularly; oil stains will cause false flame-out alarms and frequent shutdowns. Test induction sensitivity every six months and replace if signal attenuation occurs. Install away from high-temperature baking to slow aging of light-sensitive elements. 4. METAL FLEXIBLE HOSE DN13/DN20 Inspect pipe wall for cracks, oil leakage and deformation every shutdown cycle. Replace the whole hose every 1–2 years under vibrating marine working conditions to avoid oil leakage caused by metal fatigue.
General Safety Reminders Cut off power supply and close fuel valves before all maintenance operations. All spare parts are exclusive for Oilon RP-130H and shall not be replaced with incompatible models.
FAQ
Are your Oilon RP-130H burner parts genuine and certified?
Yes, all parts in our kit are genuine OEM components designed specifically for the Oilon RP-130H burner. We maintain strict compliance with original factory standards to guarantee reliable performance and safety for your marine auxiliary boiler system.
Can I install the Oilon ignition electrode A548E myself?
Our Oilon ignition electrode A548E is designed for direct plug-and-play installation without modifications. While it is straightforward to install, we recommend professional handling to ensure correct placement and safe operation under marine conditions.
Do you offer customized packaging or shipping for bulk orders?
We provide reliable logistics support tailored to industrial buyers. For bulk orders of Oilon RP-130H burner parts, including nozzles and hoses, we can coordinate shipping schedules and packaging to meet your project timelines and storage requirements.
What maintenance steps help prevent ignition failure with these burner parts?
To prevent ignition failure, regularly clean and inspect the dual atomizing nozzles and ensure the Oilon ignition electrode A548E is properly positioned. Also, check and clean the photo cell lens to avoid false flame detection alarms and maintain burner efficiency.
Download
CONTACT US
If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.