| Voltage | AC 24V |
| Frequency | 50/60 Hz |
| IP Grade | IP54 |
| Torque | 25 Nm 90° |
| Net Weight | 1.95KG |
| Size | 270*65*98mm |

Function
The main functions of the actuator motor include:
1、Drive valve: By controlling the opening and closing of the valve, adjust the inlet air volume, oil intake and other parameters of the incinerator to ensure the stability and efficiency of the incineration process.
2、Adjust the damper: Automatically adjust the opening of the damper according to the temperature and pressure parameters in the incinerator to maintain the best combustion conditions.
3、Control burner: The process of atomization, ignition and combustion of waste oil is realized by driving the rotation or movement of the burner.
Maintenance
1、Cleaning and Inspection: Regularly clean the casing and internal parts of the actuator motor to check whether there is damage or wear.
2、Lubrication and replacement: Lubricate parts that need lubrication regularly, and replace parts that are heavily worn.
3、Test and adjustment: Periodically test the performance parameters of the actuator motor (such as output force, response time, etc.), and adjust and optimize as needed.
4、Troubleshooting and repair: When the actuator motor fails, the fault troubleshooting and repair should be carried out in time to avoid affecting the normal operation of the incinerator.